Mechanical Thrombectomy by the Rolling Technique Using a Coronary Wire in a Patient with Recurrent Inferior Vena Cava Filter Thrombosis
|
|
Park Jong-Ik
Kim Su-Hong Sohn Chang-Bae Lee Sea-Won Oh Song-Hee Jung Min-Woong Park Se-Ryeong
|
|
Abstract
|
|
|
A permanent inferior vena cava (IVC) filter with anti-coagulation therapy may be considered in patients with recurrent pulmonary embolism. IVC filter thrombosis is a challenging clinical problem. Here, we report our experience in treating one such patient using mechanical thrombectomy via the rolling technique with a 0.014-inch coronary wire.
|
|
KEYWORD
|
|
Vena cava filters, Thrombosis, Thrombectomy
|
|