Difference of Time Weighted Averages in Different Seting Ups for Noise Dosimeter



Abstract
This study was designed to investigate the difference of time weighted average(TWA) of noise levels and noise doses by the different operating parameter settings such as exchange rate, threshold level and criterion level for noise dosimeter in the field measurements of noise at industrial working environments. The time weighted averages of noise level and noise doses for noise working environments were determined by noise dosimeter on 80 workers employed at 20 industrial establishments of 8 industries.
The results obtained were as follows:
1. The mean time weighted average(TWA) of the noise working environments by the operating parameter settings showed 93.4 dB(A) in 3 dB of exchange rate, 80 dB of threshold level and 90 dB of criterion level 92.0 dB(A) in 3 dB-exchange rate, 90 dB-threshold level and 90 dB-criterion level, in 90.8 dB(A) in 5 dB of exchange rate, 80 dB of threshold level and 90 dB of criterion level, and 86.7 dB(A) in S dB of exchange rate, 90 dB of threshold level and 90 dB of criterion level.
2. In group of noise level less than 90 dB(A), mean TWAs of 80 dB of threshold level were significantly higher than that of 90 dB of threshold level in 3 dB and 5 dB of exchange rate.
3. The case exceeded threshold limit value of noise was 49(61.3 %) in 3 dB, 80 dB and 90 dB setting, 44(55.0 %) in 3 dB, 90 dB, 90 dB setting, 33(41.3 %) in 5 dB, 80 dB, 90 dB setting and 26(32.5 %) in 5 dB, 90 dB, 90 dB setting.
Above considerations in mind, it is suggested that exchange rate and threshold level be specified in related laws and regulations in the evaluation of working environments noise.