Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0895420050150010052
Journal of Korean Society of Occupational and Enviromental Hygiene
2005 Volume.15 No. 1 p.52 ~ p.60
Assessment of the Accuracy on MSDS of Water-soluble Metalworking Fluids with Respect to Concentration of MEA, DEA and TEA
Lee Kwon-Seob

Sun Ok-Nam
Yoon Kyung-Sup
Park Dong-Uk
Abstract
This study was carried to assess the accuracy of material safety data sheets (MSDS) for some water-soluble etalworking fluid (MWF) with respect to mono- ethanolamine(MEA), di-ethanolamine(DEA) and tri-ethanolamine (TEA). 39 fresh and 52 used MWFs for this study were taken from the workplace. The quantification and qualification of MEA, DEA and TEA were done using ion-chromatography. Three main findings of this study were 1) EA that was not addressed in material safety & data sheets (MSDS) was found to be enough higher than 1% , 2) 33.3% of 39 fresh MWF showed ingredient and concentration of MEA, DEA and TEA in MSDS and 3) the concentrations of MEA(20.5%), DEA(41.3%) and TEA(15.4%) were much higher than those indicated in MSDS. Consequently, we concluded that the accuracy on ingredients and concentrations of MEA, DEA and TEA provided in MWF was very low. Our study recommends that the limit concentration of chemical except for carcinogen that employer has to indicate in MSDS should be lowered from 1% to 0.1% .
KEYWORD
Mono-ethanolamine, MEA, Di-ethanolamine, DEA, Tri-ethanolamine, TEA, Material Safety Data Sheets, MSDS, Metalworking Fluids, MWF