Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0895420140240010074
Journal of Korean Society of Occupational and Enviromental Hygiene
2014 Volume.24 No. 1 p.74 ~ p.78
Characterization of Noise Exposure in the Tank Gun Drill Ranges
Hwang Sung-Ho

Park Jae-Beum
Abstract
Objectives: Purpose of this study was to evaluate the noise level exposures at the different cannonball type and locations in the tank gun drill ranges.

Methods: We visited the tank gun drill ranges and measured with a sound level meter(3M Quest SoundPro¢â) with the value of Peak(dB(A)).

Results: The highest peak value of impulse noise level averaged 166.3 dB(A) at the site of loading solider. The highest peak value of impulse noise level by size of cannonball averaged 165.9 dB(A) at the 120 mm size cannonball of the tank. This result was significantly different from the other size of cannonballs such as 7.62 mm, 90 mm, and 105 mm(p < 0.001). Among the four types of soldier site on the tank, average noise levels of loading soldier, 156.6 dB(A), were higher than the other three types of soldier site (p > 0.05).

Conclusions: This study confirmed that there were needed for a proper control to reduce the amount of impulse noise exposure at the tank gun drill ranges.
KEYWORD
cannonball size, distance, impulse noise, noise exposure
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)