Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0895520140180010007
Journal of the Korean Society of Emergency Medical Technology
2014 Volume.18 No. 1 p.7 ~ p.15
Comparisons of the qualities of chest compression accordi to various positions of rescuer to patient at the in-hospital cardiopulmonary resuscitation model
Kim Gun-Nam

Choi Seong-Woo
Jang Jin-Yeong
Ryu So-Yeon
Abstract
Purpose: The purpose of the study is to evaluate the distance and location of the rescuer to patient for the effective chest compressions qualities.

Methods: The subjects were 42 students who earned the basic lifesaving technique and had informed consents to participate in the study from May 1 to 20 in 2013. The position of the rescuers included model-0(reference point), model-1(10 cm distance), model-2(20 cm distance), and model-kn(kneeling up).

Results: The mean depth of compression was 50.6¡¾6.6 mm in Model-0, 48.7¡¾8.2 mm in Model-1, 44.2¡¾10.4 mm in Model-2, and 51.8¡¾6.0 mm in Model-kn. There were statistically significant differences between each Model(p<.001).

Conclusion: The closer distance between rescuer and patient could provide more effective chest compressions. Kneeling on the bed stance provided the deeper chest compression consistently than the stool stance.
KEYWORD
Rescuers stance, Distance, CPR, Chest compression