KMID : 0896219990190010037
|
|
Journal of Daegu Health College 1999 Volume.19 No. 1 p.37 ~ p.44
|
|
Fabrication of TLDs and Its Measurement of Absorbed Dose Distribution for Electron
|
|
Park Myeong-Hwan
Kim Seong-Hwan Lee Joon-Il
|
|
Abstract
|
|
|
In this study, the highly sensitive CaSO©þ:Tm-PTFE TLDs has been fabricated for the purpose of measurement of high energy electron. CaSO©þ:Tm phosphor powder was mixed with polytetrafluoroethylene(PTFE) powder and moulded in a disk type(diameter 8.5§®, thickness 90§·/§²) by cold pressing. The batch uniformities were average deviation 3.1%. The TLDs were determined to be R_(100)£½14.5§®, R_(50)£½24.1§® and R_(p)£½31.8§®, respectively. The beam flatness were 4.5% as the variation of dose relative to the central axis over the central 80% of the field size at a maximum dose depth in a plane perpendicular to the central axis.
|
|
KEYWORD
|
|
|
|