Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 0896720030070010088
Journal of the Korean Society of Foot Surgery
2003 Volume.7 No. 1 p.88 ~ p.94
Treatment of syndesmotic injury of ankle with bioabsorbable screw
Kang Jae-Do

Kim Kwang-Yeol
Yim Moon-Sup
Kim Hyung-Chun
Kim Jin-Hyoung
Kim Seong-Hoon
Abstract
Purpose:Bioabsorbable screws are used to fix the syndesmotic injury of ankle because of no need for additional operation to remove it. The purpose of this study is to assess the efficacy of polyevolactic acid (PLLA) screws of in the treatment of the syndesmotic injury of ankle.

Material and Methods :Eight patients of the syndesmotic injury of ankle with malleolar fracture were evaluated in this study. They were managed with plate and screw fixation for malleolar fracture and polylevolactic acid screw fixation for syndesmotic injury, followed by plaster splinting for 6 weeks. Clinical and radiographic evaluation were done and functional scores were assessed.

Results: In all cases, malleolar fractures were healed without problematic widening of cyndesmosis. There were no sinus tract formation and no wound complication. Of eight patients, five had excellent results and three had good results.

Conclusions:We conclude that polyevolactic acid screw is good material for fixation of the syndesmotic injury of ankle.
KEYWORD
ankle, syndesmotic injury, bioabsorbable screw
FullTexts / Linksout information
Listed journal information