A Case of Aspiration Pneumonia after Upper Gastrointestinal Endoscopy
Nam Oun-Ouk

Jang Jin-Seok
Roh Myung-Hwan
Park Jung-Ik
Kim Hyo-Jong
Lee Jeong-Seok
Oh Sang-Yu
Ryu Seung-Hee
Abstract
In upper gastrointestinal endoscopy, intravenous anesthesia is commonly used due to its safety and improvement in patient¡¯s sat-isfaction and comfort. The aim of this approach is to improve the condition for endoscopy. Although the risks of sedation are re-ported to be very low with sufficient monitoring, we still have few risks that cannot be overlooked including aspiration pneumonia. There have been two reported cases of aspiration pneumonia after endoscopic submucosal dissection. However, to our knowledge, there has been no reports about aspiration pneumonia developing after endoscopy for a young healthy female. So, we report a first case of unexpected aspiration pneumonia after endoscopy.
KEYWORD
Gastrointestinal endoscopy, Aspiration pneumonia