Laparoscopic Removal of a Vertebral Foreign Body
Shin Hee-Chul

Park Do-Joong
Han Ho-Seong
Kim Hyung-Ho
Lee Ju-Hee
Jee Ye-Seob
Abstract
We report a case of laparoscopic removal of a retained foreign body, a broken surgical instrument, after posterior lumbar decompression and interbody fusion (PLIF) for infection control of the vertebrae. The surgical instrument was broken during PLIF surgery. However, the orthopedic surgeon could not remove the broken instrument because of bleeding and a poor operative view; the surgeon finished the operation leaving the broken surgical instrument in the vertebral body. Plain films revealed a metallic pin-like material at the anterior side of the lumbar vertebral body. Six days later, through a laparoscopic approach, the broken surgical instrument was removed without complication, and the orthopedic surgeon completed the planned operation successfully.
KEYWORD
Laparoscopy, Surgical instrument, Foreign body removal
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) ´ëÇÑÀÇÇÐȸ ȸ¿ø