Elevation of Depressed Skull Fracture with a Cup of Breast Pump and a Suction Generator
|
|
Kim Young-Jin
Kim Young-Joon Lee Sang-Koo Cho Maeng-Ki
|
|
Abstract
|
|
|
Surgical elevation of the depressed bone is known to be the conventional treatment usually recommended for a simple depressed skull fracture in the adult or pediatric age. The authors introduce, however, a case of depressed skull fracture in an infant which was elevated by means of a cup of breast pump and a suction generator without surgical elevation. In our case, without surgery, a ¡¯cup-shaped¡¯ depressed skull fracture in an infant was safely elevated with no neurological signs. This method is considered a simple, effective, safe, and alternative procedure in an infant with simple depressed skull fracture.
|
|
KEYWORD
|
|
Skull fracture, Depressed fracture, Infant, Breast pump, Suction generator
|
|