Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1001920120510030182
Journal of Korean Neurosurgical Society
2012 Volume.51 No. 3 p.182 ~ p.186
The Obturator Guiding Technique in Percutaneous Endoscopic Lumbar Discectomy
Han In-Ho

Choi Byung-Kwan
Cho Won-Ho
Nam Kyoung-Hyup
Abstract
In conventional percutaneous disc surgery, introducing instruments into disc space starts by inserting a guide needle into the triangular working zone. However, landing the guide needle tip on the annular window is a challenging step in endoscopic discectomy. Surgeons tend to repeat the needling procedure to reach an optimal position on the annular target. Obturator guiding technique is a modification of standard endoscopic lumbar discectomy, in which, obturator is used to access triangular working zone instead of a guide needle. Obturator guiding technique provides more vivid feedback and easy manipulation. This technique decreases the steps of inserting instruments and takes safer route from the peritoneum.
KEYWORD
Diskectomy, Percutaneous, Intervertebral disc disease, Endoscope
FullTexts / Linksout information
  
Listed journal information
SCI(E) ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø