KMID : 1001920120510030182
|
|
Journal of Korean Neurosurgical Society 2012 Volume.51 No. 3 p.182 ~ p.186
|
|
The Obturator Guiding Technique in Percutaneous Endoscopic Lumbar Discectomy
|
|
Han In-Ho
Choi Byung-Kwan Cho Won-Ho Nam Kyoung-Hyup
|
|
Abstract
|
|
|
In conventional percutaneous disc surgery, introducing instruments into disc space starts by inserting a guide needle into the triangular working zone. However, landing the guide needle tip on the annular window is a challenging step in endoscopic discectomy. Surgeons tend to repeat the needling procedure to reach an optimal position on the annular target. Obturator guiding technique is a modification of standard endoscopic lumbar discectomy, in which, obturator is used to access triangular working zone instead of a guide needle. Obturator guiding technique provides more vivid feedback and easy manipulation. This technique decreases the steps of inserting instruments and takes safer route from the peritoneum.
|
|
KEYWORD
|
|
Diskectomy, Percutaneous, Intervertebral disc disease, Endoscope
|
|