KMID : 1001920160590050505
|
|
Journal of Korean Neurosurgical Society 2016 Volume.59 No. 5 p.505 ~ p.511
|
|
Bioglue-Coated Teflon Sling Technique in Microvascular Decompression for Hemifacial Spasm Involving the Vertebral Artery
|
|
Lee Seong-Ho
Park Jae-Sung Ahn Young-Hwan
|
|
Abstract
|
|
|
Objective: Microvascular decompression (MVD) for hemifacial spasm (HFS) involving the vertebral artery (VA) can be technically challenging. We investigated the therapeutic effects of a bioglue-coated Teflon sling technique on the VA during MVD in 42 cases.
Methods: A bioglue-coated Teflon sling was crafted by the surgeon and applied to patients in whom neurovascular compression was caused by the VA. The radiologic data, intra-operative findings with detailed introduction of the procedure, and the clinical outcomes of each patient were reviewed and analyzed.
Results: The 42 patients included in the analysis consisted of 22 females and 20 males, with an average follow-up duration of 76 months (range 24-132 months). Intraoperative investigation revealed that an artery other than the VA was responsible for the neurovascular compression in all cases : posterior inferior cerebellar artery (PICA) in 23 patients (54.7%) and anterior inferior cerebellar artery (AICA) in 11 patients (26.2%). All patients became symptom-free after MVD. Neither recurrence nor postoperative neurological deficit was noted during the 2-year follow-up, except in one patient who developed permanent deafness. Cerebrospinal fluid (CSF) leak occurred in three patients, and one required dural repair.
Conclusion: Transposition of the VA using a bioglue-coated Teflon sling is a safe and effective surgical technique for HFS involving the VA. A future prospective study to compare clinical outcomes between groups with and without use of this novel technique is required.
|
|
KEYWORD
|
|
Hemifacial spasm , Vertebral artery , Microvascular decompression , Sling , Teflon , Bioglue
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|