Objective : To define optimal method that calculate the safe direction of cervical pedicle screw placement using computed tomography (CT) image based three dimensional (3D) cortical shell model of human cervical spine.

Methods : Cortical shell model of cervical spine from C3 to C6 was made after segmentation of in vivo CT image data of 44 volunteers. Three dimensional Cartesian coordinate of all points constituting surface of whole vertebra, bilateral pedicle and posterior wall were acquired. The ideal trajectory of pedicle screw insertion was defined as viewing direction at which the inner area of pedicle become largest when we see through the biconcave tubular pedicle. The ideal trajectory of 352 pedicles (eight pedicles for each of 44 subjects) were calculated using custom made program and were changed from global coordinate to local coordinate according to the three dimensional position of posterior wall of each vertebral body. The transverse and sagittal angle of trajectory were defined as the angle between ideal trajectory line and perpendicular line of posterior wall in the horizontal and sagittal plane. The averages and standard deviations of all measurements were calculated.

Results : The average transverse angles were 50.60¨¬¡¾6.22¨¬ at C3, 51.42¨¬ ¡¾7.44¨¬ at C4, 47.79¨¬ ¡¾7.61¨¬ at C5, and 41.24¨¬ ¡¾7.76¨¬ at C6. The transverse angle becomes more steep from C3 to C6. The mean sagittal angles were 9.72¨¬ ¡¾6.73¨¬ downward at C3, 5.09¨¬¡¾6.39¨¬ downward at C4, 0.08¨¬ ¡¾6.06¨¬ downward at C5, and 1.67¨¬ ¡¾6.06¨¬ upward at C6. The sagittal angle changes from caudad to cephalad from C3 to C6.

Conclusion : The absolute values of transverse and sagittal angle in our study were not same but the trend of changes were similar to previous studies. Because we know 3D address of all points constituting cortical shell of cervical vertebrae. we can easily reconstruct 3D model and manage it freely using computer program. More creative measurement of morphological characteristics could be carried out than direct inspection of raw bone. Furthermore this concept of measurement could be used for the computing program of automated robotic screw insertion.