Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1003820080120010131
Journal Of The Korea Institute Of Oriental Medical Diagnostics
2008 Volume.12 No. 1 p.131 ~ p.141
A study on the characteristic of electrogastrography according to the heat-cold patternization
Haa Song-Yong

Kim Min-Yong
Park Young-Jae
Park Young-Bae
Abstract
Background: In relation to a diagnosis of Korean Medicine, heat-cold is one of the most important indicators for evaluation. In spite of this importance, there has not been the study that tries to examine the change of indicators in an electrogastrography (EGG) according to the heat-cold patternization.

Objective: The objective of this study is to establish the correlation between the heat-cold patternization and indicators of EGG by means of Standardized Questionnaire for Heat-Cold Patternization. Method: To conduct this study, we used the method as follows: Before conducting EGG, subjects were requested to give answers to the questionnaire which was developed by Kim. Before EGG, subjects were demanded to fast for more than 8 hours and then eat the test meal. Before eating the test meal(test meal: two slices of bread, 4oz of apple juice), EGG signals were detected for 30 minutes, and then subjects could eat the test meal for 10 minutes. After eating the test meal, EGG signals were detected for 30 minutes.

Results: 1. There was a negative correlation between heat score and the power ratio of channel 1 and channel 2 of EGG. There was a positive correlation between cold score and the power ratio of channel 1 of EGG. 2. There was a positive correlation between heat score and pre-prandial gastric arrhythmia in the channel 1, 2 and 4 of EGG. There was a negative correlation between cold score and post-prandial gastric arrhythmia in the channel 1, 2 and 3 of EGG. 3. There was a negative correlation between heat score and normal pre-prandial gastric slow wave in the channel 1, 2 and 4 of EGG. There was a positive correlation between cold score and normal post-prandial gastric slow wave in the channel 3 of EGG.

Conclusions: From the results above, we could conclude as follows: Indicators of EGG and cold score presented a positive correlation, and heat score displayed a negative correlation. As a result, to apply EGG to a diagnosis of functional indigestion, the application of EGG to subjects who have heat patternization would increase the reliability of a diagnosis.
KEYWORD
EGG, Questionnaire for Heat-Cold Patternization
FullTexts / Linksout information
Listed journal information