Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1003820120160010019
Journal Of The Korea Institute Of Oriental Medical Diagnostics
2012 Volume.16 No. 1 p.19 ~ p.26
Development of the Cardiovascular Simulator for Pulse Diagnosis Study
Lee Ju-Yeon

Shin Sang-Hoon
Abstract
Objectives: The aim of this study is to develop a cardiovascular simulator that can reproduce blood pressure pulse and blood flow similar to those of the human body.

Methods: In order to design a system similar to the human cardiovascular system, the required performances were determined by investigating the hemodynamic characteristics of the heart and the arterial system. Main organ to be imitated is heart in simulator. The rest of the system was minimally designed. Also, a blood pressure and blood flow measurement system was developed for measuring the results.

Results: The developed system showed blood pressure pulse at similar range of the human aorta. The result waveform include primary wave caused by ventricular systole except reflected wave.

Conclusions: The blood pressure and blow flow patterns were replicated by the simulator. These patterns were similar to those of the human body. The system will play an important role in studying pulse diagnostics.
KEYWORD
cardiovascular system, simulator, blood pressure, blood flow, pulse diagnosis
FullTexts / Linksout information
Listed journal information