KMID : 1004520110270010073
|
|
Journal of Dental Rehabilitation and Applied Science 2011 Volume.27 No. 1 p.73 ~ p.79
|
|
The Effect of Titanium on the Castability of Cobalt-Chrome Alloy
|
|
Ryu Su-Kyoung
Chung Hee-Jeong Vang Mong-Sook Yang Hong-So Lim Hyun-Phil Yun Kwi-Dug Park Sang-Won
|
|
Abstract
|
|
|
Purpose of this experiment is to evaluate the effect of titanium on the castability when the titanium is added to the Co-Cr alloy. Raw materials Cobalt, Chrome, Molybdenum, Silicon, Manganase, Carbon, Nitrogen, Titanium were weighted and prepared. BiosilF (Degudent, Germany) was the control group. To the experimental group, different weight percent of titanium was added from 1 wt% to 4 wt%. The wax pattern is 30 X 40 cm in size, rectangular in shape and has total of 160 grids. Centrifugal machine (Neutrodyne Easy Ti: Manfredy) was used for casting. For evaluation of the castability, the number of complete grids was counted by visual inspection and X-ray inspection. The test showed similar castability with the control group in the titanium addition of 1 wt% to 3 wt%. The titanium addition of 4 wt% showed poor result. With titanium lower than 4 wt%, the experiment metals showed proper castability with high expectation of successful clinical use.
|
|
KEYWORD
|
|
castability, cobalt-chrome alloy, grid, partial denture, titanium
|
|