KMID : 1004720070060010034
|
|
Korean Journal of Endourology 2007 Volume.6 No. 1 p.34 ~ p.37
|
|
Another Method to Ligate Renal Vein during Laparoscopic Nephrectomy
|
|
Jeong Young-Beom
|
|
Abstract
|
|
|
Application of the endovascular gastrointestinal anastomosis (GIA) stapler has become a standard procedure to control renal vein during laparoscopic nephrectomy. However, device malfunction resulting in significant complications has been reported. We introduce a safe, simple and effective technique using Hem-o-lok¨Þ (Weck Closure Systems, Research Triangle Park, USA) clips and Endoloop¨Þ (Sejong Medical co., Paju-city, Kyungki-do, Korea) suture for renal vein ligation during laparoscopic nephrectomy.
|
|
KEYWORD
|
|
Laparoscopy, Nephrectomy, Renal vein, Ligation
|
|
FullTexts / Linksout information
|
|
|
|