Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1007519920010010012
Food Science and Biotechnology
1992 Volume.1 No. 1 p.12 ~ p.16
Determination of L-Lactic Acid in Foods with Enzyme Electrode
Park, In-Seon
Kim, Jung-Ho/Kim, Soo-Jung/Noh, Bong-Soo
Abstract
An enzyme electrode for L-lactate measurements was prepared with an immobilized lactate oxidase fixed to an oxygen electrode. At optimal pH and temperature, this electrode was sensitive to 0.025 mM L-lactate. There is less than 4£¥ of the response for L-lactate in various interference such as D-lactate, malate, citrate, ascorbate, propionate, glutamate, aspartate, succinate, oxalate and acetate. This enzyme electrode was used for determination of L-lactate in various foods. The L-lactate comcentrations for kimchi, yogurt, soybean milk, wine and takju were 151.8-367.5, 323-411, 32.0, 120.4 and 63.7§·/100§¢, respectively.
KEYWORD
FullTexts / Linksout information
Listed journal information
SCI(E) ÇмúÁøÈïÀç´Ü(KCI)