Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1011420090140020031
Journal of Korean Ophthalmic Optics Society
2009 Volume.14 No. 2 p.31 ~ p.34
Optical Performance Analysis of the Eye which it Follows in Iris Eccentricity
Kim Bong-Hwan

Han Sun-Hee
Abstract
Purpose: We are to analyze optically how to affect the eye related with movement of the iris.

Methods: Using the schematic eye to have the crystalline lens of the radial GRIN and the spherical GRIN forms that come to be planned in existing, the iris centre was moved 0.5 mm with nasal direction in order to be identical with the real eye. Also, considering that the iris centre move according to increase of the pupil size, the iris centre was moved 0.4 mm with temporal direction to analyze the optical performance change of the eye respectively.

Results: Because of decrease in the spherical aberration, the schematic eye with nasal direction 0.5 mm eccentricity of the iris showed a different consequence plentifully compared with the performance of the real eye. Besides, the schematic eye with temporal direction 0.4 mm eccentricity of the iris showed that the spherical aberration somewhat increased.

Conclusions: In case of design of the schematic eye with the similar real eye performance which the iris centre was moved 0.5 mm with nasal direction, we need to research about aspheric coefficient of optical constants of each refracting surface considering the performance change of a spherical aberration, a peripheral power error and astigmatism etc, owing to change of the real eye hence to be affected by the iris movement.
KEYWORD
Iris, Eccentricity, Finite schematic eye, Aberration
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)