Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1011420110160010061
Journal of Korean Ophthalmic Optics Society
2011 Volume.16 No. 1 p.61 ~ p.64
Design of the Finite Schematic Eye with GRIN Crystalline LensConsidering Iris Eccentricity
Kim Bong-Hwan

Han Sun-Hee
Abstract
Purpose: The purpose of this study was to design the finite model eye with GRIN lens similar to actual eye, which considered the effect of iris eccentricity on eyes.

Methods: By using the finite model eye with Radial GRIN and Spherical GRIN, which were designed previously, the location of iris was eccentrically located by 0.5 mm in the direction of nose to show the same eye as actual one. For ray trace and design, Code V program of Optical Research Associates (ORA) was adopted.

Results: Designed model eye was compared to actual eye depending on iris eccentricity and the model eye which showed reduced value was corrected according to actual eye to design the finite model eye.

Conclusions: Ocular optical systems considered the point that iris was a rotational asymmetry and designed the finite model eye with GRIN lens, which was similar to actual eye, by considering the effect of iris eccentricity on eye.
KEYWORD
Iris, Eccentricity, Finite schematic eye, GRIN, Aberration