Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1011420130180020165
Journal of Korean Ophthalmic Optics Society
2013 Volume.18 No. 2 p.165 ~ p.171
Changes in KVA Resulting from Correction Condition of Refractive Error
Shim Hyun-Suk

Kim Sang-Hyun
Kang Hye-Sook
Abstract
Purpose: This study are to analyze and to compare between pupillary size, reaction time, refractive error, corrected vision, dominant eye, static visual angle (SVA) and kinetic visual acuity (KVA) of male and female college students, to measure KVA of them in full correction and to identify changes of KVA by +0.50 D and ?0.50 D spherical power addition respectively in full correction condition. Methods: KVA, SVA, pupillary size, reaction time, refractive error, corrected vision and dominant eye of 40 male and 40 female optical science students were measured by utilizing KOWA AS-4A, reaction time measurement program, subjective refractometer, and objective refractometer, and KVAs were measured when +0.50 D/?0.50 D were added in both eyes respectively. Results: Binocular KVA of whole subjects was 0.45¡¾0.22, and in monocular KVAs were 0.36¡¾0.19 for right eye and 0.34¡¾0.19 for left eye, and binocular KVA was significantly higher than monocular KVA. It appeared that the better SVA was, the better KVA was in significant way, and in terms of refractive error the less myopia amount was, the better KVA was, but it was not significant statistically. The lower astigmatism was, the slightly and significantly higher KVA was when dividing between equal or less than ?1.00 D astigmatism group and over ?1.00 D astigmatism group. In resulting from correction condition of refractive error KVAs were 0.45¡¾0.22 for full correction, 0.26¡¾0.15 for +0.50 D addition, 0.48¡¾0.22 for ?0.50 D addition which indicates that KVA in over myopia correction was significantly the highest and followed by full correction and under correction. Similar findings were revealed in both male and female, and KVA of male was better than female in comparing between male and female. There was no significantly different KVA between dominant eye and non-dominant eye. Conclusions: Accordingly, it is concluded that KVA is related with far distance SVA, astigmatism amount, and refractive error amount except a dominant eye. Through this research, it was found that prescription for enhancing KVA is to make full correction or to overcorrect slightly myopia.
KEYWORD
Kinetic visual acuity, Static visual angle, Refractive error, Under correction, Over correction
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)