KMID : 1011820190600010035
|
|
Investigative and Clinical Urology 2019 Volume.60 No. 1 p.35 ~ p.39
|
|
Evaluation of pain and catheter-related bladder discomfort relative to balloon volumes of indwelling urinary catheters: A prospective study
|
|
Zugail Ahmed S.
Pinar Ugo Irani Jacques
|
|
Abstract
|
|
|
Purpose: To evaluate patients' tolerance to indwelling urinary catheters (IUCs) before and after reducing their balloon volumes. IUCs are a source of discomfort or pain.
Materials and Methods: All consecutive patients hospitalized in our department with IUCs were included during the study period with some exclusion. Each patient was his/her own control before and two hours after reduction of the balloon volume (RBV) by half using two types of assessments, a visual analog scale for pain and a catheter-related bladder discomfort (CRBD) symptom questionnaire.
Results: Forty-nine patients were included in our study that completed the assessments. The mean scores for pain before and after RBVs were 2.80 and 2.02, respectively. The difference was significant (p<0.05). The mean grades of the CRBD before and after RBVs were 1.02 and 0.75, respectively. The difference was significant (p<0.05).
Conclusions: A 50% RBV has shown a significant amelioration in tolerating the catheter.
|
|
KEYWORD
|
|
Clinical protocols, Pain management, Treatment outcome, Urinary bladder, Urinary catheters
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|