Purpose: It is not easy to detect carbon monoxide (CO) leakage, and CO-intoxicated patients do not show a specific set of symptoms. The aims of this study are to clinically evaluate patients with CO gas intoxication from a CO leak at an underground shopping center, and to discuss the establishment of a disaster prevention plan.

Methods: A total of 51 patients intoxicated by CO gas exposure in a gas disaster at a underground shopping center in Seoul on September 8, 2006 were enrolled in this study, and the patients¡¯¡¯ medical records were retrospectively reviewed.

Results: The mean patient age was $29.4{\pm}6.3$. The initial mean COHb level was $14.98{\pm}6.97%$. The number of patients with COHb greater than 25% was three, and six patients experienced a syncopal attack. Only one patient-was treated with hyperbaric oxygen therapy. However, none of the patients complained of severe neurologic or cardiovascular symptoms.

Conclusion: The symptoms of CO intoxication are non-specific and difficult to define, and the detection of CO leak-age is difficult. Thus, workplaces should be equipped with leakage sensors and automatic alarm systems and should have develop disaster prevention plans.
KEYWORD
Carbon monoxide, Intoxication, Disaster prevention