Influence of Superficial Heat and Deep Heat for Lumbo-sacral Segment on H-Reflex
Yon Se-Won

Lim Young-Eun
Lee Jeong-Woo
Abstract
Purpose: The purpose of this study was to investigate influence of superficial heat and deep heat for lumbo-sacral segment on H-reflex.

Methods: Subjects of this research were 12 normal men and women (6 men and 6 women) and they were assigned to superficial heat group (6) and deep heat group (6). Heat treatment was applied between Th12-L2 by placing them at prone posture. superficial heat was applied for 20 min at 30 cm height with infrared lamp. Deep heat was applied for 20 mm at 5 cm height with 100 watt of microwave diathermy. H-reflex used diagnostic electromyography, active electrode was placed at muscle belly of medial gastrocnemius muscle at prone posture and electrical stimulation was given to posterior tibial nerve. Measurement was made before and after experiment and 10 min. and 20 min. after experiment. All data were analyzed with window 12.0 program, comparison of differences among measured items of groups according to repeated measurement was made with repeated measures ANOVA and significance level a was 0.05.
Results: M latency at latency analysis showed little changes at two groups. H latency was reduced a little immediately after experiment and recovered to original state, there was significant difference. In analysis of amplitude, Mmax amplitude showed rise a little immediately after.
KEYWORD
Superficial Heat, Deep Heat, H-reflex