Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1021120120240040431
Korean Journal of Occupational and Environmental Medicine
2012 Volume.24 No. 4 p.431 ~ p.440
The Characteristics of Tinnitus and Hearing Threshold : In Workers with Noise Induced Hearing Loss from a Hospital Setting
Kim Nam-Jeong

Park Hyoung-Ouk
Sim Chang-Sun
Lee Choong-Ryeol
Kwon Young-Joo
Lee Ji-Ho
Abstract
Objectives: This study was carried out to define the relationship between the characteristics of tinnitus and hearing threshold (puretone and speech) in workers with noise induced hearing loss (NIHL).

Methods: A total of 189 cases(378 ears) from workers with compensation claims for NIHL during 2004-2009 were investigated. Various factors, including age, work carriers, body mass index (BMI), blood pressure, noise exposure level of worksite hearing threshold, speech discrimination score, pitch match, and loudness of tinnitus were analyzed.

Results: The average hearing threshold of all subject was 44.2 dBHL, puretone audiometry thresholds in subjects with tinnitus were lower than the non-tinnitus group (except at 8000 Hz). Using speech audiometry, the tinnitus group showed a lower speech recognition threshold and speech discrimination score. The tinnitus group also had an average tinnitus frequency of 4195.2 Hz, loudness of 73.6 dB, and tinnitus sensation average of 6.0 dBSL. These frequencies of tinnitus were in the lowest puretone audiometry frequencies. Tinnitus loudness had a strong relationship with puretone and speech audiometry thresholds.

Conclusions: In cases beyond moderate hearing loss, the tinnitus group had a better puretone (except 8000 Hz) and speech hearing status, and most comfortable loudness (MCL) level. In addition, puretone and speech audiometry thresholds increase with tinnitus loudness.
KEYWORD
Tinnitus, Noise induced hearing loss, Worker¡¯s compensation
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø