KMID : 1024020210510030261
|
|
Imaging Science in Dentistry 2021 Volume.51 No. 3 p.261 ~ p.269
|
|
Evaluation of the radiopacity of restorative materials with different structures and thicknesses using a digital radiography system
|
|
Yaylaci Ayla
Karaarslan Emine Sirin Hatirli Huseyin
|
|
Abstract
|
|
|
Purpose: The aim of this study was to evaluate the radiopacities of various types of restorative materials with different thicknesses compared with enamel, dentin, and aluminum.
Materials and Methods: Four bulk-fill resins, 2 hybrid ceramics, 2 micro-hybrid resin composites, 6 glass ionomer-based materials, 2 zinc phosphate cements, and an amalgam were used in the study. Twelve disk-shaped specimens were prepared from each of 17 restorative materials with thicknesses of 1 mm, 2 mm, and 4 mm (n=4). All the restorative material specimens with the same thickness, an aluminum (Al) step wedge, and enamel and dentin specimens were positioned on a phosphor storage plate and exposed using a dental X-ray unit. The mean gray values were measured on digital images and converted to equivalent Al thicknesses. Statistical analyses were performed using 2-way analysis of variance and the Bonferroni post hoc test (P<0.05).
Results: Radiopacity was significantly affected by both the thickness and the material type (P<0.05). GCP Glass Fill had the lowest radiopacity value for samples of 1 mm thickness, while Vita Enamic had the lowest radiopacity value for 2-mm-thick and 4-mm-thick samples. The materials with the highest radiopacity values after the amalgam were zinc phosphate cements.
Conclusion: Significant differences were observed in the radiopacities of restorative materials with different thicknesses. Radiopacity was affected by both the material type and thickness.
|
|
KEYWORD
|
|
Dental Materials, Radiography, Dental, Digital
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|
|