Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1024519970060040391
Journal of the Environmental Sciences
1997 Volume.6 No. 4 p.391 ~ p.397
A Study on Charateristic of Modern Packing, 25mm NSW-ring, ppm by Absorption of NH3 gas
Shin Eun-Jae

Park Jin-Sick
Kim Jang-Ho
Jang Seong-Ho
Abstract
The study was carried out to demonstrate the superiority of used packing in view of energy saving and efficiency of mass transfer, comparing with conventional packing. The results are as follows : 1. Owing to low Pressure drop under high load. 25mm NSW-ring, pp. can cause energy saving 2. The unique magnitudes of used packing are as follows =5.78, m=0.67, n=0.46 3. Used packing can make high efficiency including energy saving because of low pres sure drop per the number of transfer unit. To rate the characteristic of packing, It should be carried out that the measurement of pressure drop per packing height and per the number of transfer unfit. This study demonstrated the superiority of used packing by carring out above experiment and could be used as basic reference for design and predicting efficiency of packing tower which is tilled with same packing.
KEYWORD
Packing, Absorption, NSW-ring, Mass Transfer, Pressure Drop
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)