KMID : 1024520000090030223
|
|
Journal of the Environmental Sciences 2000 Volume.9 No. 3 p.223 ~ p.228
|
|
Evaluation to Purification Capacity of Pollutants by Column Test with the tidal flat sediment
|
|
Kim Jong-Gu
You Sun-Jae
|
|
Abstract
|
|
|
The purpose of this study is to evaluate the purification capacity of pollutants by column test with the tidal flat sediment. Sediment materials were taken from Chunjangdae tidal flat which located in Chungnam Seochungun. The column tests were conducted on four conditions(R1 : raw sewage filtered by G2 filter, R2 : sterilized sewage after filtered by GF/C filter, R3 : R2 /filtered(membrane) seawater (1:1), R4 : R2 /filtered(membrane) seawater(1:2)). The results of this study may be summarized as followed ; The removed COD by column tests were increased according to increasing the quantity of sewage. During the column tests of 580min, the total removed ammonia nitrogen were 90.1mg for R1, 81.0mg for R2, 27.6mg for R3 and 4.1mg for R4. The result was similar to COD experiment. During the 580min, the total removed total-phosphates were 3.4mg for R1, 4.2mg for R2, 5.6mg for R3 and 2.0mg for R4. The removal efficiency of Pb and Cd for R3 and R4 reactor were higher than R1 and R2 reactor. The remove of heavy metal by the column test was high in sample with seawater. But in the initial 20min, the adsorbed Pb and Cd showed about 3% of the total adsorbed Pb and Cd during 580min.
|
|
KEYWORD
|
|
tidal flat sediment, column test, purification capacity, removal efficiency
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|
|