Pilot Scale Assessment of DOC and THMs Removal in Conventional Water Treatment System
Lee Choong-Dae

Lee Yoon-Jin
Abstract
This research aims to investigate the behavior of organic matter that causes bacterial re-growth and the formation of disinfectant by-products such as THM in water treatment, and to optimize conditions for a more efficient and conventional water facility. THM removed 51 % and 12 % through coagulation/sedimentation and filtration using a selected conventional system. In this experiment, the removal ratio of DOC was highest at 68 % when the Gt value was 42,000 and lowest at 41 % when the Gt value was 30,000. 77-84 % of total DOC was removed during coagulation/sedimentation, and 15-23 % was removed during filtration. When Gt values were between 30,000 and 66,000, over 50 % of high molecular matter above 10 K during coagulation/sedimentation was removed. Turbidity removed 98 % when the G1 value was 66,000. As the Gt value increased, the turbidity removal ratio increased. Turbidity removed over 20 % during the filtration process.
KEYWORD
DOC, THM, Molecular Weight Distribution, Gt