Sewage Sludge Thickening Using Electroflotation
Kim Dong-Seog

Park Young-Seek
Abstract
The performance of EF (electroflotation) on the thickening of activated sludge were investigated using laboratory scale batch flotation reactor. In this paper, the effects of parameters such as electrode material, NaCl dosage, initial sludge concentration and electrode distance were examined. The results showed that the performance for sludge thickening of the five electrodes lay in: Pt/Ti > Ru/Ti > Ir/Ti > Ti mesh > Ti plate. The more NaCl dosage was high, the more sludge was thickened and the shorter thickening time was obtained. However, considering the final thickening time and sludge concentration, optimum NaCl dosage was 0.5 g/L. Thickening time and sludge concentration was not affected by electrode distance. In DAF (dissolved air flotation) system, optimum recycle ratio was 40% and thickening performance was lower than that of the EF.
KEYWORD
Electrotlotation, Current, Electrode, NaCl, Sludge thickening