KMID : 1024520100190030371
|
|
Journal of the Environmental Sciences 2010 Volume.19 No. 3 p.371 ~ p.377
|
|
Treatment of Dyeing Wastewater by Magnetic-Biological Treatment System
|
|
Lee Sun-Ha
|
|
Abstract
|
|
|
The purpose of this study is to investigate treatment efficiency in dyeing wastewater treatment by the high rate aeration system(HRA) and a combination of the HRA with magnetized wastewater treatment system(MWS). At the hydraulic retention time of 16hr, 24hr, 30hr, BOD removal efficiencies of HRA system were 93%, 96% and 98%, combination of the HRA with MWS system were 94%, 96.8% and 98.2%, respectively. In case of COD, at the hydraulic retention time of 16hr, 24hr, 30hr, COD removal efficiencies of HRA system were 66%, 77.1% and 83.1%, combination of the HRA with MWS system were 70.2%, 80.1% and 86.6%, respectively. The comparison of the HRA and combination of the HRA with MWS, effluent BOD of the former was 22.7mg/§¤ and the latter was 19.4mg/§¤, therefore biological treatment efficiency identified to increase by the MWS.
|
|
KEYWORD
|
|
High rate aeration system, Magnetized wastewater treatment system, BOD volumetric Loading, Dyeing wastewater
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|
|