Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1024520100190040509
Journal of the Environmental Sciences
2010 Volume.19 No. 4 p.509 ~ p.516
Characterizations of Airborne Fiber Particle Concentrations in Public Facilities and Schools
Park Jeong-Ho

Suh Jeong-Min
Abstract
This study was investigated the characteristics of indoor air concentration of fiber particles in 30 public facilities and 245 schools by PCM (phase contrast microscopy). Also SEM/EDX (scanning electron microscope / energy dispersive using X-ray analysis) was used to obtain physicochemical information of asbestos fiber and to classify asbestos and non-asbestos of fiber particles. The airborne concentrations of fiber particles were 0.0009¡¾0.0009 counts/mL in public facilities and 0.0012¡¾0.0006 counts/mL in schools by PCM. All the samples were satisfied with the IAQ (indoor air quality) level of 0.01counts/mL. In classification of 4 type shapes, over 80% of the fiber particles were identified as single fiber type. And this study analysed airborne fiber particles in 4 sites for identifying asbestos of by SEM/EDX. The asbestos fibers in most samples could not be found.
KEYWORD
Indoor air, Fiber particle, Asbestos, PCM, SEM/EDX
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)