KMID : 1024520110200050639
|
|
Journal of the Environmental Sciences 2011 Volume.20 No. 5 p.639 ~ p.645
|
|
Flotation Efficiency of the DAF Pump System for Mixing and Coagulation Conditions in Raw Drinking Water
|
|
Ahn Kab-Hwan
Lee Chang-Han
|
|
Abstract
|
|
|
This study found that flotation efficiencies for removing algae and micro particles in raw water were optimized on mixing intensity and time of the mixing and flocculation conditions with a continuous DAF system. It is more efficient for mixing intensity at 23.1 and time at 660 s(Gt value : 15246) to float flocculated floc with the raw water in M water treatment plant. Flotation efficiency was more than about 0.9 when operated pressure and A/S ratio were sustained at 5 and up to 0.056 . The continuous DAF system made by the study could be continuously operated for 20 days and sustained not exceeding 4 NTU with raw water with low turbidity(13.4~9.8 NTU).
|
|
KEYWORD
|
|
DAF, Algae, Coagulation, Flocculation, Drinking water
|
|
FullTexts / Linksout information
|
|
|
|
Listed journal information
|
|
|