Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1024520120210070883
Journal of the Environmental Sciences
2012 Volume.21 No. 7 p.883 ~ p.890
Evaluation of Malodor Release and Control Devices in Charcoal Manufacturing Facility
Jeong Ju-Young

Seo Byeong-Ryang
Kim Jae-Hyuck
Chin Sung-Min
Jurng Jong-Soo
Abstract
Emission characteristics of gaseous odor compounds emitted from the charcoal manufacturing process were investigated, and evaluated the odor removal efficiency of odor control devices. It was found that the measured odor dilution ratio of emission gases ranged from 10,000 to 44,814, which exceed largely the emission standard in the stack. Methylmercaptan, trimethylamine, hydrogen sulfide, acetaldehyde were turned out as major odor compounds of the charcoal manufacturing process. It was revealed that the odor removal ratio of odor control devices were very low due to the its improper maintenance and wrong design.