KMID : 1024520140230122045
Journal of the Environmental Sciences
2014 Volume.23 No. 12 p.2045 ~ p.2056
Pressure Drop Predictions Using Multiple Regression Model in Pulse Jet Type Bag Filter Without Venturi
Suh Jeong-Min

Park Jeong-Ho
Cho Jae-Hwan
Jin Kyung-Ho
Jung Moon-Sub
Yi Pyong-In
Hong Sung-Chul
Sivakumar, S.
Choi Kum-Chan
Abstract
In this study, pressure drop was measured in the pulse jet bag filter without venturi on which 16 numbers of filter bags
(¨ª140 ¡¿ 850 §¤) are installed according to operation condition(filtration velocity, inlet dust concentration, pulse pressure, and pulse interval) using coke dust from steel mill. The obtained 180 pressure drop test data were used to predict pressure drop with multiple regression model so that pressure drop data can be used for effective operation condition and as basic data for economical design.
The prediction results showed that when filtration velocity was increased by 1%, pressure drop was increased by 2.2%
which indicated that filtration velocity among operation condition was attributed on the pressure drop the most. Pressure was dropped by 1.53% when pulse pressure was increased by 1% which also confirmed that pulse pressure was the major factor affecting on the pressure drop next to filtration velocity. Meanwhile, pressure drops were found increased by 0.3% and 0.37%, respectively when inlet dust concentration and pulse interval were increased by 1% implying that the effects of inlet dust concentration and pulse interval were less as compared with those changes of filtration velocity and pulse pressure. Therefore,the larger effect on the pressure drop the pulse jet bag filter was found in the order of filtration velocity(Vf), pulse pressure(Pp),inlet dust concentration(Ci), pulse interval(Pi).
Also, the prediction result of filtration velocity, inlet dust concentration, pulse pressure, and pulse interval which showed
the largest effect on the pressure drop indicated that stable operation can be executed with filtration velocity less than 1.5
m/min and inlet dust concentration less than 4 g/m3. However, it was regarded that pulse pressure and pulse interval need to be adjusted when inlet dust concentration is higher than 4 g/m3
. When filtration velocity and pulse pressure were examined,operation was possible regardless of changes in pulse pressure if filtration velocity was at 1.5 m/min. If filtration velocity was
increased to 2 m/min. operation would be possible only when pulse pressure was set at higher than 5.8 kgf/cm2
. Also, the prediction result of pressure drop with filtration velocity and pulse interval showed that operation with pulse interval less than 50 sec. should be carried out under filtration velocity at 1.5 m/min. While, pulse interval should be set at lower than 11 sec. if filtration velocity was set at 2 m/min.
Under the conditions of filtration velocity lower than 1 m/min and high pulse pressure higher than 7 kgf/cm2
, though pressure drop would be less, in this case, economic feasibility would be low due to increased in installation and operation cost since scale of dust collection equipment becomes larger and life of filtration bag becomes shortened due to high pulse pressure
KEYWORD
Pressure drop, Pulse jet type, Bag filter, Without venturi, Filtration velocity