Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1033720120130020125
Archives of Craniofacial Surgery
2012 Volume.13 No. 2 p.125 ~ p.129
Easy Molding Technique of Methylmethacrylate Implant Using Plaster and Rapid Prototyping Model in Cranioplasty
Park Ki-Rin

Kim Yong-Ha
Kim Tae-Gon
Lee Jun-Ho
Ha Ju-Ho
Abstract
Purpose:Methylmethacrylate is the most commonly used alloplastic material in cranioplasty. However during the polymerization of methylmethacrylate, a significant exothermic reaction takes place. This reaction may result in thermal injury to the brain tissue and other soft tissues. Also it is difficult to make three-dimensional methylmethacrylate implant that is perfectly matched to the defect during the operation time. We report on the molding technique of methylmethacrylate implant using plaster mold and the rapid prototyping model in cranioplasty.

Methods:A 44-year-old male was referred to the department for severe frontal hollowness. He was involved in an automobile accident resulting in large frontal bone defect with irregular margin. The preformed patient-specific methylmethacrylate implant was made using plaster mold and the rapid prototyping model before the operative day. The methylmethacrylate implant was placed in the frontal defect and rigidly fixed with miniplates and screws on the operative day.

Results:The operation was performed in an hour. In the 6 months follow-up period, there were no complications. Patient was satisfied with the results of cranioplasty.

Conclusion:Safe cranioplasty was performed with the preformed patient-specific methylmethacrylate implant using plaster mold and the rapid prototyping model. The result of this method was satisfactory, aesthetically and functionally.
KEYWORD
Methylmethacrylate, Cranioplasty
FullTexts / Linksout information
Listed journal information