Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1036120160080010035
Korean Society of Medicine & Therapy Science
2016 Volume.8 No. 1 p.35 ~ p.41
Usefulness of Tri-axial Accelerometer on Balance Evaluation under Static Standing in Stroke
Kim Hyung-Geun

You Young-Youl
Abstract
Objective: The purpose of this study is to suggest the usefulness of accelerometer on postural sway in stroke patients.

Method: We conducted experiments in which 27 stroke patients stand on on firm surface with opening eyes, and on balance pad with closing eyes by tri-axial accelerometers. We used t-test to compare the differences of two posture during static standing and also the differences between falling and non-falling.

Results: There were significant differences according to static standing on firm surface with opening eyes, and on balance pad with closing eyes(p<.05). Also, there were significant differences in static standing on balance pad with closing eyes between falling and nonfalling (p<.05).

Conclusion: The results of this study showed Accelerometers have been proposed as a quantitative measure of balance during static standing.
KEYWORD
balance, postural sway, stroke, tri-axial accelerometer
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI)