Internal Fixation with a Locking T-Plate for Proximal Humeral Fractures in Patients Aged 65 Years and Older
Yum Jae-Kwang

Seong Min-Kyu
Hong Chi-Woon
Abstract
Background: The purpose of this study was to evaluate the clinical and radiographic outcomes of internal fixation with locking T-plates for osteoporotic fractures of the proximal humerus in patients aged 65 years and older.

Methods: From January 2007 through to December 2015, we recruited 47 patients aged 65 years and older with osteoporotic fractures of the proximal humerus. All fractures had been treated using open reduction and internal fixation with a locking T-plate. We classified the fractures in accordance to the Neer classification system; At the final follow-up, the indicators of clinical outcome?the range of motion of the shoulder (flexion, internal rotation, and external rotation) and the presence of postoperative complications?and the indicators of radiographic outcome?the time-to-union and the neck-shaft angle of the proximal humerus?were evaluated. The Paavolainen method was used to grade the level of radiological outcome in the patients.

Results: The mean flexion was 155.0¡Æ (range, 90¡Æ?180¡Æ), the mean internal rotation was T8 (range, T6?L2), and the mean external rotation was 66.8¡Æ (range, 30¡Æ?80¡Æ). Postoperative complications, such as plate impingement, screw loosening, and varus malunion were observed in five patient. We found that all patients achieved bone union, and the mean time-to-union was 13.5 weeks of the treatment. The mean neck-shaft angle was 131.4¡Æ at the 6-month follow-up. According to the Paavolainen method, ¡°good¡± and ¡°fair¡± radiographic results each accounted for 38 and 9 of the total patients, respectively.

Conclusions: We concluded that locking T-plate fixation leads to satisfactory clinical and radiological outcomes in elderly patients with proximal humeral fractures by providing a larger surface area of contact with the fracture and a more rigid fixation.
KEYWORD
Proximal humerus, Osteoporotic fractures, Locking T-plate, Internal fixation
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed