Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1036220180210040246
Clinics in Shoulder and Elbow
2018 Volume.21 No. 4 p.246 ~ p.251
Delayed Lateral Row Anchor Failure in Suture Bridge Rotator Cuff Repair: A Report of 3 Cases
Jeong Jae-Jung

Ji Jong-Hun
Park Seok-Jae
Abstract
Compared to single row repair, use of lateral row anchors in suture bridge rotator cuff repair enhances repair strength and increases foot-print contact area. If a lateral knotless anchor (push-in design) is inserted into osteoporotic bone, pull-out of the lateral row anchor can developed. However, failures of lateral row anchors have been reported at several months after surgery. In our cases, even though complete cuff healing occurred, delayed pull-out of the lateral row anchor in the suture bridge repair occurred. In comparison to a conventional medial anchor, further biomechanical evaluation of the pull-out force, design, and insertion angle of the lateral anchor is needed in future studies. We report three cases with delayed pull-out of lateral row anchor in suture bridge rotator cuff repair with a literature review.
KEYWORD
Lateral row anchors, Suture bridge rotator cuff repair, Pull-out, Repair strength, Footprint
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed