Objective : This study sought to investigate the clinical survival rate of two implants with different surfaces: resorbable blasting media (RBM)-treated and calcium metaphosphate (CMP)-coated implant.
Study design : SSII non-submerged implants (Osstem, Seoul, Korea) were placed in a total of 48 patients with mean age of 38.8. At least 31 patients in the experimental group had a CMP-coated implant, and 1 patient in the control group received a, RBM surface implant. The evaluation period was between April 2006 and December 2007. Radiographs, periotest, clinical periodontal examination, and prosthetic adjustment and occlusion were used.
Results : The survival rate of the experimental and control groups after 1 year was 97.2% and 100%, respectively. The Wald confidence interval reported for the experimental group was not inferior to the control group.
Conclusion : No significant differences were found between the RBM and CMP groups. The observed data suggest that CMP-coated methods can provide favorable clinical results for the functioning and healing of dental implants.
|
|