KMID : 1036620170050041021
|
|
Journal of Korean Clinical Health Science 2017 Volume.5 No. 4 p.1021 ~ p.1025
|
|
Effect of Hydrogel lens and Silicone-Hydrogel lens on Corneal thickness
|
|
Seo Jung-Ick
|
|
Abstract
|
|
|
Purpose: Changes in corneal thickness after wearing hydrogel lens and silicone-hydrogel lens with different oxygen transmission rates wew syudied.
Methods: Experiments were performed on 11 subjects(22 eyes). corneal thickness was measured after wearing contact lenses for 8 hours. Corneal thickness was measured using ORB Scan ¥±(ver.3.14)
Results: In the results of the corneal thickness measurement by direction, in the case of the hydrogel-tor lens, the center thickness was 33.63§, the nasal was 34.29§, the temporal was 27.17§, the inferior was 27.17§, the superior was 18.90§, and change rates were 6.28%, 5.71%, 5.40%, 4.75% and 3.09%, respectively. In the results of the corneal thickness measurement by diameter, in the case of the hydrogel-tor lens, the center was 33.63§, the mid-peripheral was 28.19§, the peripheral was 24.18§, and change rates were 6.28%, 4.76%, and 3.79%, respectively.
Conclusions: The hydrogel lenses with relatively low oxygen transmission rates resulted in a significant increase in thickness over the entire cornea compared to silicon-hydrogel lenses with high oxygen transmission rates.
|
|
KEYWORD
|
|
corneal thickness, hydrogel lens, silicone-hydrogel lens
|
|