KMID : 1037520210370020017
|
|
Vascular Specialist International 2021 Volume.37 No. 2 p.17 ~ p.17
|
|
Gallium-67 Scan with Single Photon Emission Computed Tomography for the Evaluation and Monitoring of Infected Abdominal Aortic Aneurysms: A 10-Year Case Series
|
|
Kwok Hoi-Ming
Luk Wing-Hang Cheng Lik-Fai Pan Nin-Yuan Chan Ho-Fung Ma Johnny Ka-Fai
|
|
Abstract
|
|
|
Purpose: This study aimed to evaluate the role of gallium-67 single photon emission computed tomography (SPECT) with contrast computed tomography (CT) in the evaluation and monitoring of infected abdominal aortic aneurysms (IAAA).
Materials and Methods: A retrospective cohort analysis was performed using prospectively collected data of consecutive patients with IAAA in Princess Margaret Hospital in Hong Kong between January 2010 and December 2020. The patients were identified using the Radiology Information System.
Results: All five patients had proven IAAA on CT and/or metabolic imaging. Among them, three were further supported by positive blood culture results. Gallium- 67 SPECT with contrast CT was useful in the detection of residual disease, monitoring, and detection of recurrence.
Conclusion: Gallium-67 SPECT with contrast CT is helpful for evaluating IAAA. It serves an important role in guiding management, especially during long-term follow-up.
|
|
KEYWORD
|
|
Gallium isotope, Single photon emission computed tomography scan, Infected aneurysm, Abdominal aortic aneurysm, Diagnostic imaging
|
|
FullTexts / Linksout information
|
|
|
|