Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1037620150020010022
Pediatric Emergency Medicine Journal
2015 Volume.2 No. 1 p.22 ~ p.28
Removal of Blunt Esophageal Foreign Body Using Foley Catheter in Children
Lee Jun-Young

Kwak Jae-Ryoung
Min Young-Gi
Lee Ji-Sook
Abstract
Purpose: Foreign body ingestion is a common cause for children to visit the emergency department. Removal of esophageal foreign body was usually done by an endoscopy. After Bigler introduced the Foley catheter technique for esophageal foreign body in 1966, many studies were performed regarding such technique. However, only a few researchers in Korea have attempted to report this technique. This study reports a 10-year experience of the Foley catheter removal method for blunt esophageal foreign body at a single center in Korea.

Methods: Medical records of patients who were treated as esophageal foreign body with Foley catheters between March 2005 and February 2015 were retrospectively reviewed. Their clinical characteristics and outcomes were evaluated.
Results: A total of 73 patients were treated as esophageal foreign body impaction using the Foley catheter method. Foreign body removals were successful in 67 (91.8%) cases. Six failed cases were treated with esophagoscopy or endoscopy. The mean age was 3.7 years old. The most common foreign body was a coin (80.8%). Foreign bodies were lodged at the upper esophagus level most frequently (79.5%), followed by the middle esophagus (12.3%) and the lower esophagus (6.8%). During the removal procedure, 43.8% of patients were sedated, and 95.9% were treated with fluoroscopy. There were no positive correlations between the removal success and sedation (P=0.54) or using a fluoroscopy (P=0.23). In 69 cases (94.5%), there were no serious complications. However, in one patient, complications, such as vomiting, fever, and esophageal ulceration were observed. One patient complained fever and esophageal ulceration. In 3 (60%) of the total 5 patients with button battery ingestion, serious complications, such as fever or esophageal ulceration, occurred.
Conclusion: Removal of blunt esophageal foreign body using a Foley catheter in children is a useful and relatively safe method. However, patients with button battery ingestion need more attention when trying the Foley catheter removal technique.
KEYWORD
Foreign Bodies, Esophagus, Urinary Catheters
FullTexts / Linksout information
 
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed