Usefulness of a new polyvinyl alcohol hydrogel (PVA-H)-based simulator for endoscopic submucosal dissection training: a pilot study
|
|
Lee Dong-Seok
Lee Gin-Hyug Kim Sang-Gyun Lee Kook-Lae Kim Ji-Won Jeong Ji-Bong Jung Yong-Jin Kang Hyoun-Woo
|
|
Abstract
|
|
|
Background/Aims : We developed a new endoscopic submucosal dissection (ESD) simulator and evaluated its efficacy and realism for use training endoscopists.
Methods : An ESD simulator was constructed using polyvinyl alcohol hydrogel sheets and compared to a previous ESD simulator. Between March 1, 2020, and December 30, 2021, eight expert endoscopists from three different centers analyzed the procedure-related factors of the simulator. Five trainees performed gastric ESD exercises under the guidance of these experts.
Results : Although the two ESD simulators provided overall favorable outcomes in terms of ESD-related factors, the new simulator had several benefits, including better marking of the target lesion¡¯s limits (p<0.001) and overall handling (p<0.001). Trainees tested the usefulness of the new ESD simulator. The complete resection rate improved after 3 ESD training sessions (9 procedures), and the perforation rate decreased after 4 sessions (12 procedures).
Conclusions : We have developed a new ESD simulator that can help beginners achieve a high level of technical experience before performing real-time ESD procedures in patients.
|
|
KEYWORD
|
|
Endoscopic submucosal dissection, Endoscopy, Hydrogels, Polyvinyl alcohol, Simulation training
|
|