Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1041720200320010040
Annals of Occupational and Environmental Medicine
2020 Volume.32 No. 1 p.40 ~ p.40
Related factors for preserving firefighter's pulmonary function
Kim Seong-Gyu

Jeon Ye-Eun
Ryu Hye-Seung
Lee Mi-Young
Chung In-Sung
Abstract
Background: Firefighters are constantly exposed to harmful substances in the respiratory tract and require management measures. We comprehensively compared factors affecting the lung function of firefighters to identify management measures that can reduce the deterioration of lung function.

Methods: A cross-sectional study was conducted in 1,108 male firefighters. Subjects were surveyed with self-written questionnaires that included a history of smoking, number of workouts per week, work department, and medical history, including diseases that could affect lung function. Body mass index was calculated using an automatic body measurement instrument and body fat, body fat percentage, muscle mass, and skeletal muscle mass were measured using Inbody 770. Based on the body weight obtained from body measurements, skeletal muscle mass height-adjusted skeletal muscle index (hSMI) compared to height was determined. For lung function, forced expiratory volume in one second (FEV1), forced vital capacity (FVC), FEV1/FVC, and peak expiratory flow (PEF) were measured using a spirometer HI-801. Analysis of variance and independent t-tests were performed for univariate analysis of factors that could affect lung function, and multiple regression analysis was performed for multivariate analysis.

Results: When the factors relating lung function were analyzed using regression analysis, FEV1 was negatively correlated with age, body fat percentage, and duty year, positively with height and hSMI. FVC increased with height and hSMI, decreased with age, body fat percentage, and duty year. FEV1/FVC was related with age, height, body fat percentage and working history. Height and muscle mass were analyzed as related factors on PEF. When the analysis was conducted on firefighters who exercised more than 3 times a week, working history had lower relation with FEV1 and body fat percentage had no relation with FEV1/FVC.

Conclusion: We suggest management measures to reduce body fat percentage and increase skeletal muscle mass to maintain lung function in firefighters.
KEYWORD
Firefighters, Pulmonary function test, Body composition
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed