Reference ranges for autonomic function tests in healthy Korean adults
Park Kee-Hong

Kim Byoung-Joon
Kang Sa-Yoon
Oh Sun-Young
Sohn Eun-Hee
Song Kyeong-Jin
Shin Jin-Hong
Kang Kyoung-Hwa
Cho Eun-Bin
Jeong Hee-Jeong
Lee Hyung
Kim Hyun-Ah
Kim Rock-Bum
Park Ki-Jong
Abstract
Background: The standardized autonomic function test has become widely available. However, there are no reference data for this test for the Korean population. This study explored reference data for sudomotor and cardiovagal function tests for the Korean population.

Methods: The sweat volume by quantitative sudomotor axon reflex test, heart-rate response to deep breathing (HRdb), expiration:inspiration (E:I) ratio, and Valsalva ratio (VR) were measured in 297 healthy Korean volunteers aged from 20 to 69 years. Multivariate regression analysis was performed to evaluate the effects of age, sex, and body mass index on these variables. The 2.5th, 5th, 10th, 90th, 95th, and 97.5th percentile values were obtained for each investigation.

Results: The sweat volume was higher in males than in females. The HRdb and E:I ratio were negatively correlated with age, and were higher in males than in females. The VR was negatively correlated with age, but it was not correlated with sex.

Conclusions: This study has provided data on the reference ranges for sudomotor and cardiovagal function tests in healthy Korean adults.
KEYWORD
Autonomic nervous system, Reference range, Sweating, Parasympathetic nervous system