Analytical results of a fixed concentration of Pb, Cd and Cr in the synthetic copper standard solution (RMs) for using the matrix no matched standard calibration curve at various wavelength by ICP showed that accuracy (140 ¢¦ 1,070% in case of Pb) is very poor at all wavelengths because of the Cu matrix effect. Analytical results of a fixed concentration of Pb, Cd and Cr in the different concentration solutions of Cu showed that found values were on the increase or decrease as the rate of a regular equation as the concentration of Cu was increased. Accuracies by the Cu matching method in the analysis of Pb, Cd and Cr in the synthetic copper standard solution (RMs) were higher than 99.9%.
KEYWORD
Cu matching method, Cu matrix effect, Matrix matched standard calibration curve