Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1101320100420030155
Korean Journal of Clinical Laboratory Science
2010 Volume.42 No. 3 p.155 ~ p.160
Correlation of Gender/Age and Measurement Indices of Transcranial Doppler Ultrasonography
Jin Bok-Hee

Abstract
Transcranial Doppler ultrasonography (TCD) allows measurement of blood flow velocity to be made from the basal intracerebral vessels. Blood flow velocity in TCD is highly affected not only by blood vessel diameter, blood flow volume, blood viscosity, but also age and sex. Therefore, the study is focused on the correlation between TCD measurement index and sex/age. Subjects were 214 (male 147, famale 67) who had TCD for headache and stroke evaluations at Dongguk University Ilsan Hospital neurology department from December 2009 to April 2010. Sex did not show significant differences with mean flow velocity (MFV), peak systolic flow velocity (PSFV), end diastolic flow velocity (EDFV), pulsatility index (PI) and resistance index (RI) in middle cerebral artery (MCA). Although age also did not show significant differences with MFV and PSFV, EDFV has statistically decreased with age, and PI and RI has statistically increased with age. In addition, age showed significant correlation with MFV, EDFV, PI and RI, but not with PSFV. Therefore, TCD is definitely correlated with age and sex, so that those influencial factors must be considered when being tested.
KEYWORD
Transcranial Doppler ultrasonography (TCD), Measurement index, Gender, Age
FullTexts / Linksout information
Listed journal information