Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.
KMID : 1103720070560020161
Journal of the Korean Society of Radiology
2007 Volume.56 No. 2 p.161 ~ p.170
Assessment of the Viable Fraction of Hepatocytes by Mangafodipir Trisodium Enhanced Functional MR Imaging: Preliminary Report in Animal Models
Cho Soon-Koo

Jeon Yong-Sun
Lee Kyung-Hee
Seo Chang-Hae
Song Jang-Ho
Park In-Suh
Han Seung-Baik
Abstract
Purpose: We designed this study to evaluate the feasibility of using mangafodipir trisodium enhanced functional liver imaging (MT-FLI) for assessing the viable fraction of hepatocytes (VFH) in the liver.

Materials and Methods: We evaluated the change of VFH with using MT-FLI before and after inducing acute hepatic necrosis (AHN) with CCl4 in the liver of 15 beagle dogs. The MR imaging was performed on a 1.5T MRI unit with using the EFGRE-3D sequence (TR/TE=4.7/1.1 msec; flip angle: 20.0degree). We evaluated the linear dependence of the density of viable hepatocytes in AHN on the MR images as compared to that in the corresponding normal livers (DAHN/DN) on the VFH in their pathologic specimens, and the change of the VFH from the MT-FLI on that of the laboratory findings (AST, ALT, albumin, bilirubin, PT, ICG-R15) before and after AHN induction.

Results: The mean+/-SD of the VFH from the MT-FLI in AHN was 61.2+/-10.7% of that of the normal ones. The DAHN/DN showed strong positive linear dependence on the VFH in their pathologic specimens (?=.769, p<.05). The change of the VFH from MT-FLI showed high linear dependence on that of all the above-mentioned laboratory findings (?<-.933 or >.938, p<.05).

Conclusion: The MT-FLI seems to be a feasible method for measuring VFH in the liver.
KEYWORD
Liver, Liver function, Magnatic resonance(MR) volume measurement, Animals
FullTexts / Linksout information
Listed journal information
ÇмúÁøÈïÀç´Ü(KCI) KoreaMed ´ëÇÑÀÇÇÐȸ ȸ¿ø