Balloon Tamponade Treatment of a Stent-graft Related Rupture with a Splenic Artery Pseudoaneurysm: A Case Report
|
|
Kim Si-Hyung
Kim Young-Hwan
|
|
Abstract
|
|
|
An arterial rupture resulting from stent-graft placement of a splenic artery pseudoaneurysm is a life-threatening complication and immediate endovascular or surgical treatment is indicated. We report a case of a stent-graft related splenic artery rupture treated solely with a prolonged balloon catheter tamponade, which resulted in preservation of vessel patency.
|
|
KEYWORD
|
|
Splenic artery, Stent, Aneurysm, false
|
|